Table 3

Average peak compressive strength of SCBs at ambient conditions and after 2 h of standard fire exposure

Testing conditionsAverage compressive strength [MPa]
Control (0%)5%10%20%30%40%50%
Crumb rubber-based walls
At ambient conditions20.0 ± 0.519.2 ± 0.218.4 ± 0.79.2 ± 0.28.1 ± 0.55.7 ± 0.35.6 ± 0.3
Post 2 h fire exposure15.9 ± 0.618.3 ± 0.312.3 ± 0.611.5 ± 0.37.3 ± 0.64.6 ± 0.33.9 ± 0.4
Plastic-based walls
At ambient conditions20.0 ± 0.513.0 ± 0.712.3 ± 0.312.1 ± 0.611.1 ± 0.29.0 ± 0.47.9 ± 0.6
Post 2 h fire exposure15.9 ± 0.610.1 ± 0.67.9 ± 0.19.2 ± 0.45.3 ± 0.34.5 ± 0.33.8 ± 0.2
Source(s): Authors’ own work