Table 2.

Test parameters and results (Sandén et al., 2017)

Test parametersValue
Borehole diameter: m0·08
Installation time: min60
Flow rate: l/s1·0
Diameter of bentonite block: m0·074
Length of bentonite block: m0·25
Area of annular gap: cm27·3
Velocity in annular gap: m/s1·378
Mass loss (test results)10·3%