Summary of tests performed on loose specimens
| Identification | Moulding | Consolidation | End of test | ||
|---|---|---|---|---|---|
| ν0 | p′0: kPa | νc | ψ0 | ecs | |
| 100F_0S_50_F | 1·81 | 50 | 1·80 | 0·02 | 0·78 |
| 80F_20S_50_F | 1·80 | 50 | 1·81 | 0·08 | 0·73 |
| 70F_30S_50_F | 1·79 | 50 | 1·78 | 0·06 | 0·72 |
| 60F_40S_50_F | 1·80 | 50 | 1·79 | 0·11 | 0·68 |
| 0F_100S_50_F | 2·08 | 50 | 2·04 | 0·13 | 0·91 |
| 100F_0S_1000_F | 1·80 | 1000 | 1·75 | 0·06 | 0·69 |
| 80F_20S_1000_F | 1·77 | 1000 | 1·70 | 0·08 | 0·62 |
| 70F_30S_1000_F | 1·77 | 1000 | 1·69 | 0·11 | 0·58 |
| 60F_40S_1000_F | 1·77 | 1000 | 1·65 | 0·11 | 0·54 |
| 0F_100S_1000_F | 2·07 | 1000 | 1·79 | 0·12 | 0·67 |
| Identification | Moulding | Consolidation | End of test | ||
|---|---|---|---|---|---|
| 100F_0S_50_F | 1·81 | 50 | 1·80 | 0·02 | 0·78 |
| 80F_20S_50_F | 1·80 | 50 | 1·81 | 0·08 | 0·73 |
| 70F_30S_50_F | 1·79 | 50 | 1·78 | 0·06 | 0·72 |
| 60F_40S_50_F | 1·80 | 50 | 1·79 | 0·11 | 0·68 |
| 0F_100S_50_F | 2·08 | 50 | 2·04 | 0·13 | 0·91 |
| 100F_0S_1000_F | 1·80 | 1000 | 1·75 | 0·06 | 0·69 |
| 80F_20S_1000_F | 1·77 | 1000 | 1·70 | 0·08 | 0·62 |
| 70F_30S_1000_F | 1·77 | 1000 | 1·69 | 0·11 | 0·58 |
| 60F_40S_1000_F | 1·77 | 1000 | 1·65 | 0·11 | 0·54 |
| 0F_100S_1000_F | 2·07 | 1000 | 1·79 | 0·12 | 0·67 |