Summary of analyses of frequency of engagement of DfA practices (one-sample t-test)
| Summary of analyses of the frequency of engagement of DfA practices (one-sample t-test) | ||||||
|---|---|---|---|---|---|---|
| S/N | DfA practices | Cronbach’s alpha = 0.919, test value = 3.50 | ||||
| T-value | Mean | Std. deviation | Rank | p-value | ||
| DP 1 | Designing to ensure the functional resilience of buildings | 9.195 | 4.08 | 0.977 | 5th | 0.000t |
| DP 2 | Creating designs having in mind the structural durability of the building | 13.456 | 4.27 | 0.876 | 2nd | 0.000t |
| DP 3 | Outlaying the structure to have space-plan flexibility | 12.389 | 4.23 | 0.909 | 3rd | 0.000t |
| DP 4 | Keeping a balance of structural durability and space-plan flexibility in my designs | 11.128 | 4.16 | 0.907 | 4th | 0.000t |
| DP 5 | Endorsing the use of durable elements in my design specification | 13.880 | 4.28 | 0.858 | 1st | 0.000t |
| DP 6 | Recommending the use of flexible connection methods within the building | 6.196 | 3.88 | 0.935 | 9th | 0.000t |
| DP 7 | Designing with materials that can be easily dismantled | 2.635 | 3.68 | 1.062 | 15th | 0.009t |
| DP 8 | Creating a structural grid that allows for a modular building skin | 7.263 | 3.99 | 1.040 | 6th | 0.000t |
| DP 9 | Designing space plans based on standard material dimensions | 4.560 | 3.79 | 0.971 | 10th | 0.000t |
| DP 10 | Incorporating design measures that maintain comfortability and a healthy indoor environment | 7.138 | 3.97 | 1.012 | 7th | 0.000t |
| DP 11 | Creating designs using bioclimatic and biophilic principles | 2.971 | 3.71 | 1.074 | 13th | 0.003t |
| DP 12 | Organizing building layers (i.e. the site, structure, skin, services, space plan and stuff) according to their end-of-life span in my designs | 3.519 | 3.74 | 1.054 | 12th | 0.001t |
| DP 13 | Designing to ensure that building service systems are separated | 3.729 | 3.75 | 1.047 | 11th | 0.000t |
| DP 14 | Recommending the use of recyclable materials in my design specifications | 2.156 | 3.65 | 1.087 | 16th | 0.032t |
| DP 15 | Endorsing the reuse of materials in my designs | 1.577 | 3.61 | 1.032 | 18th | 0.116 |
| DP 16 | Creating designs to ensure the possibility of vertical expansions | 1.273 | 3.59 | 1.074 | 19th | 0.204 |
| DP 17 | Using building elements that can be reassembled in my design | 0.235 | 3.52 | 1.109 | 20th | 0.815 |
| DP 18 | Designing with a deconstruction plan in mind | 1.800 | 3.64 | 1.157 | 17th | 0.073 |
| DP 19 | Ensuring that components can be selectively disassembled | 2.791 | 3.71 | 1.143 | 14th | 0.006t |
| DP 20 | Creating designs that preserve the heritage of buildings | 6.836 | 3.95 | 1.009 | 8th | 0.000t |
| Summary of analyses of the frequency of engagement of DfA practices (one-sample | ||||||
|---|---|---|---|---|---|---|
| S/N | DfA practices | Cronbach’s alpha = 0.919, test value = 3.50 | ||||
| Mean | Std. deviation | Rank | ||||
| DP 1 | Designing to ensure the functional resilience of buildings | 9.195 | 4.08 | 0.977 | 5th | 0.000t |
| DP 2 | Creating designs having in mind the structural durability of the building | 13.456 | 4.27 | 0.876 | 2nd | 0.000t |
| DP 3 | Outlaying the structure to have space-plan flexibility | 12.389 | 4.23 | 0.909 | 3rd | 0.000t |
| DP 4 | Keeping a balance of structural durability and space-plan flexibility in my designs | 11.128 | 4.16 | 0.907 | 4th | 0.000t |
| DP 5 | Endorsing the use of durable elements in my design specification | 13.880 | 4.28 | 0.858 | 1st | 0.000t |
| DP 6 | Recommending the use of flexible connection methods within the building | 6.196 | 3.88 | 0.935 | 9th | 0.000t |
| DP 7 | Designing with materials that can be easily dismantled | 2.635 | 3.68 | 1.062 | 15th | 0.009t |
| DP 8 | Creating a structural grid that allows for a modular building skin | 7.263 | 3.99 | 1.040 | 6th | 0.000t |
| DP 9 | Designing space plans based on standard material dimensions | 4.560 | 3.79 | 0.971 | 10th | 0.000t |
| DP 10 | Incorporating design measures that maintain comfortability and a healthy indoor environment | 7.138 | 3.97 | 1.012 | 7th | 0.000t |
| DP 11 | Creating designs using bioclimatic and biophilic principles | 2.971 | 3.71 | 1.074 | 13th | 0.003t |
| DP 12 | Organizing building layers (i.e. the site, structure, skin, services, space plan and stuff) according to their end-of-life span in my designs | 3.519 | 3.74 | 1.054 | 12th | 0.001t |
| DP 13 | Designing to ensure that building service systems are separated | 3.729 | 3.75 | 1.047 | 11th | 0.000t |
| DP 14 | Recommending the use of recyclable materials in my design specifications | 2.156 | 3.65 | 1.087 | 16th | 0.032t |
| DP 15 | Endorsing the reuse of materials in my designs | 1.577 | 3.61 | 1.032 | 18th | 0.116 |
| DP 16 | Creating designs to ensure the possibility of vertical expansions | 1.273 | 3.59 | 1.074 | 19th | 0.204 |
| DP 17 | Using building elements that can be reassembled in my design | 0.235 | 3.52 | 1.109 | 20th | 0.815 |
| DP 18 | Designing with a deconstruction plan in mind | 1.800 | 3.64 | 1.157 | 17th | 0.073 |
| DP 19 | Ensuring that components can be selectively disassembled | 2.791 | 3.71 | 1.143 | 14th | 0.006t |
| DP 20 | Creating designs that preserve the heritage of buildings | 6.836 | 3.95 | 1.009 | 8th | 0.000t |