Specifications of the hot water heat pump and the solar PV system
| Equipment | Specifications | Details |
|---|---|---|
| Hot water heat pump | Rated heating capacity | 3.6 kW |
| Power supply | 240 V single phase/10 Amp | |
| Compressor type | Rotary | |
| Compressor input capacity | 900 W | |
| Refrigerant | Propane | |
| Tank storage capacity | 260 L | |
| Maximum water temperature | 60 °C when using the heat pump alone, 70 °C when using a heating element | |
| Karra-250Wp PV module | Number of PV panels | 12 |
| Panel dimension (L x W x H) | 1,667 1000 40 mm | |
| Total panel area and installed location | 19.2 and on a north-facing roof with 5 pitch | |
| Reference cell temperature and insolation | 25 °C and 1000 W/m2 | |
| Modules short-circuit current at reference conditions | 8.8 A | |
| Module open-circuit voltage at reference conditions | 37.7 V | |
| Module voltage at max power point at reference conditions | 30 V | |
| Module current at max power point at reference conditions | 8.3 A | |
| Number of cells per panel | 60 | |
| Karra-300Wp PV module | Number of PV panels | 24 |
| Panel dimension (L x W x H) | 1,667 1000 40 mm | |
| Total panel area and installed location | 40.0 and on a north-facing roof with 30 pitch | |
| Reference cell temperature and insolation | 25 °C and 1000 W/m2 | |
| Modules short-circuit current at reference conditions | 9.65 A | |
| Module open-circuit voltage at reference conditions | 40.1 V | |
| Module voltage at max power point at reference conditions | 32.93 V | |
| Module current at max power point at reference conditions | 9.11 A | |
| Number of cells per panel | 60 |
| Equipment | Specifications | Details |
|---|---|---|
| Hot water heat pump | Rated heating capacity | 3.6 kW |
| Power supply | 240 V single phase/10 Amp | |
| Compressor type | Rotary | |
| Compressor input capacity | 900 W | |
| Refrigerant | Propane | |
| Tank storage capacity | 260 L | |
| Maximum water temperature | 60 °C when using the heat pump alone, 70 °C when using a heating element | |
| Karra-250Wp PV module | Number of PV panels | 12 |
| Panel dimension (L x W x H) | 1,667 | |
| Total panel area and installed location | 19.2 | |
| Reference cell temperature and insolation | 25 °C and 1000 W/m2 | |
| Modules short-circuit current at reference conditions | 8.8 A | |
| Module open-circuit voltage at reference conditions | 37.7 V | |
| Module voltage at max power point at reference conditions | 30 V | |
| Module current at max power point at reference conditions | 8.3 A | |
| Number of cells per panel | 60 | |
| Karra-300Wp PV module | Number of PV panels | 24 |
| Panel dimension (L x W x H) | 1,667 | |
| Total panel area and installed location | 40.0 | |
| Reference cell temperature and insolation | 25 °C and 1000 W/m2 | |
| Modules short-circuit current at reference conditions | 9.65 A | |
| Module open-circuit voltage at reference conditions | 40.1 V | |
| Module voltage at max power point at reference conditions | 32.93 V | |
| Module current at max power point at reference conditions | 9.11 A | |
| Number of cells per panel | 60 |