Table 1

Variations of thresholds, spacing and alarm logic in different regions

RegionThresholdsSpacingAlarm logic
EuropeΔT 40–60°C + Absolute 100–120°C (ambient corrected)60–100 km (denser near tunnels, hazmat routes)Multi-level (warning/alert/critical), OCC rulebooks
North AmericaAbsolute ∼105–115°C (prescriptive FRA rules)40–65 km (25–40 miles) prescriptive spacingBinary stop/inspect at next siding for hotbox
IndiaMixed absolute/differential, integrated into EHMSDense corridors, centralised coverage (>900 sites)EHMS: multi-level alarms integrated with OCC
ChinaAdaptive + AI classifiers, multi-spectral IRStrategic siting on HSR and freight corridorsAI-enhanced, multi-sensor fusion, digital twin pilots
AustraliaAbsolute + differential, tuned for >30 t axle loadsClose spacing (30–50 km) on heavy-haul corridorsMulti-level, combined HABD + acoustic/vibration pilots
Source(s): UIC (2024), ProRail (2020), RISSB (2022), Indian Railways (2022), CARS (2019) 

or Create an Account