Table 7

Overview of the parameters of the compared laser systems

ParameterReference systemAdditive system
Max. output power / W3.63.2
Slope efficiency / %52.9 ± 0.351.1 ± 0.8
Standard deviation of the output power over 8 h / %0.20.8
Optic-to-optical efficiency / %50.4 ± 0.145.7 ± 0.4
M21.421.32
Pointing RMS / µrad1.919.9
Notes:

Optical-to-optical efficiency and power stability are calculated and measured, respectively, at maximum output power. Same applies for the M2. The accuracy of the power values is 3.0 % according to the specification of the power head. For the pointing, the beam position is detected over a period of 2 h

Source: Kranert, 2024 