Description of events highlighted in figures
| Event | Elapsed time: days | Description |
|---|---|---|
| 1 | 5266.07 | Start of pressurisation of canister |
| 1a | 5268.56 | Isolation of canister |
| 1b | 5269.14 | Gas reconnected to canister |
| 1c | 5269.44 | Isolation of canister |
| 2 | 5277.23 | Depressurisation of canister to fix leak |
| 2a | 5278.41 | Canister pressure increased to 2000 kPa |
| 2b | 5279.24 | Canister pressure increased to 4000 kPa |
| 2c | 5279.90 | Canister pressure increased to 4950 kPa |
| 3 | 5291.18 | Start of gas ramp 1 |
| 4 | 5316.39 | End of gas ramp 1 |
| 5 | 5325.91 | Start of gas ramp 2 |
| 6 | 5329.40 | Accidental leakage of gas from injection system |
| 7 | 5333.07 | End of gas injection |
| 8 | 5410.86 | First evidence of gas entry (pressure increase in UB902) |
| 9 | 5420.25 | Stress relief and pressure increase in FL901 |
| Event | Elapsed time: days | Description |
|---|---|---|
| 1 | 5266.07 | Start of pressurisation of canister |
| 1a | 5268.56 | Isolation of canister |
| 1b | 5269.14 | Gas reconnected to canister |
| 1c | 5269.44 | Isolation of canister |
| 2 | 5277.23 | Depressurisation of canister to fix leak |
| 2a | 5278.41 | Canister pressure increased to 2000 kPa |
| 2b | 5279.24 | Canister pressure increased to 4000 kPa |
| 2c | 5279.90 | Canister pressure increased to 4950 kPa |
| 3 | 5291.18 | Start of gas ramp 1 |
| 4 | 5316.39 | End of gas ramp 1 |
| 5 | 5325.91 | Start of gas ramp 2 |
| 6 | 5329.40 | Accidental leakage of gas from injection system |
| 7 | 5333.07 | End of gas injection |
| 8 | 5410.86 | First evidence of gas entry (pressure increase in UB902) |
| 9 | 5420.25 | Stress relief and pressure increase in FL901 |
Sharing content requires targeting cookies to be enabled. Please update your cookie preferences to use this feature.