Summary of first three gas ramps conducted in test GT4
| GT4 | Units | Gas ramp 1 | Gas ramp 2 | Gas ramp 3 |
|---|---|---|---|---|
| Start time | day | 2988.07 | 3038.04 | 3087.24 |
| Start volume | ml | 3750 | 2570 | 1960 |
| Injection rate | ml.h−1 | 2.45 | 1.2 | 0.725 |
| Start pressure | kPa | 1868 | 2868 | 3867 |
| End pressure | kPa | 2867 | 3856 | 4852 |
| Ramp duration | days | 23.9 | 23.1 | 23.2 |
| STP flow during flow | m3.s−1 | 1.25–1.48 × 10−8 | 0.93–1.24 × 10−8 | 7.51–9.41 × 10−9 |
| Pressure hold duration | days | 26.0 | 26.1 | 52.6 |
| Flow during hold | µmol.d−1 | 282 | 538 | 651 |
| GT4 | Units | Gas ramp 1 | Gas ramp 2 | Gas ramp 3 |
|---|---|---|---|---|
| Start time | day | 2988.07 | 3038.04 | 3087.24 |
| Start volume | ml | 3750 | 2570 | 1960 |
| Injection rate | ml.h−1 | 2.45 | 1.2 | 0.725 |
| Start pressure | kPa | 1868 | 2868 | 3867 |
| End pressure | kPa | 2867 | 3856 | 4852 |
| Ramp duration | days | 23.9 | 23.1 | 23.2 |
| m3.s−1 | 1.25–1.48 × 10−8 | 0.93–1.24 × 10−8 | 7.51–9.41 × 10−9 | |
| Pressure hold duration | days | 26.0 | 26.1 | 52.6 |
| Flow during hold | µmol.d−1 | 282 | 538 | 651 |