Data relating to gas injection tests conducted in canister filters FL903 and FU910
| Filter | Test | Gas ramps | Start : days | End: days | Time gap: days | Peak pressure: kPa | Time at peak: days |
|---|---|---|---|---|---|---|---|
| FL903 | GT1 | 2 | 917.32 | 1010.03 | 917.32 | 5666 | 972.24 |
| GT2 | 4 | 1577.40 | 1967.98 | 567.36 | 5868 | 1769.65 | |
| GT4 | 4 | 2988.08 | 3283.02 | 1020.11 | 6174 | 3205.31 | |
| GT6 | 1 | 5230.29 | 5263.95 | 1947.26 | 6437 | 5235.96 | |
| FU910 | GT3 | 4 | 2257.23 | 2614.46 | 2257.23 | 5192 | 2490.37 |
| GT5 | 1 | 5183.27 | 5220.47 | 2568.82 | 5347 | 5202.57 |
| Filter | Test | Gas ramps | Start : days | End: days | Time gap: days | Peak pressure: kPa | Time at peak: days |
|---|---|---|---|---|---|---|---|
| FL903 | GT1 | 2 | 917.32 | 1010.03 | 917.32 | 5666 | 972.24 |
| GT2 | 4 | 1577.40 | 1967.98 | 567.36 | 5868 | 1769.65 | |
| GT4 | 4 | 2988.08 | 3283.02 | 1020.11 | 6174 | 3205.31 | |
| GT6 | 1 | 5230.29 | 5263.95 | 1947.26 | 6437 | 5235.96 | |
| FU910 | GT3 | 4 | 2257.23 | 2614.46 | 2257.23 | 5192 | 2490.37 |
| GT5 | 1 | 5183.27 | 5220.47 | 2568.82 | 5347 | 5202.57 |