Table 4.

Pull-out resistance measured in the centrifuge model tests and calculated moment capacity, mobilised by the axial mechanism for an idealised 2 × 1 pile group

Centrifuge testInstallationPluviationPileg-levelVpo: MNMult: MNm
SNF-A01 (04)Pre-installed buriedCurtainAlluminum502.58022.740
SNF-A02 (03)1g-JackedCurtainAlluminum504.49028.470
SNF-A05Pre-installed buriedCurtainAlluminum1002.75023.250
SNF-A061g-JackedCurtainAlluminum1004.29027.870
SNF-A07Pre-installed buriedHopperAlluminum502.90023.700
SNF-A081g-JackedHopperMiniature RC505.12530.375