Table 4.

Sample of assessment of potential thermal energy customers and locations

Extraction locationPotential demand sourceDemand profileInternal or externalConnection typeHeat network in place
Manchester Tunnel north portal
Mixed commercial, healthcare and residential customersCommercial, healthcare, residentialExternalHeat networkYes
Future over-site developmentResidential and commercialExternalHeat networkNo
Trackside buildingsCommercialInternalDirect connectionN/A
Medium- and low-density housingResidentialExternalHeat networkNo
Birchfields Road ventilation shaft
University campus and sports centreCommercial and residentialExternalDirect connectionN/A
Low-density housing, two schoolsResidential and educationExternalHeat networkNo
Palatine Road ventilation shaft
HotelCommercialExternalHeat networkNo
Low-density housingResidentialExternalHeat networkNo
Wilmslow Road ventilation shaft
HospitalHealthcareExternalDirect connectionN/A
Medium-density housingResidentialExternalHeat networkNo
Middlewich Street ventilation shaft
Civic and municipal buildingsCommercialExternalHeat networkYes
Medium-density housingResidentialExternalHeat networkReliant on expansion plans
School, care home, crematoriumCommercial, educationExternalHeat networkNo
Cowley Way ventilation shaft
Rail station (existing)CommercialInternalDirect connectionN/A
Business parkCommercial and industrialExternalHeat networkNo
University campusEducation and residentialExternalDirect connectionN/A
Trackside buildingsCommercialInternalDirect connectionN/A
SupermarketCommercialExternalEitherN/A