Summary of maximum tested loads and measured O-Cell expansions under SLS and ULS loads
| Test pile ID | 1 | 2 | 2A | 3 |
|---|---|---|---|---|
| Maximum tested load (MN, upward/downward) | 51.65 (29.67)* | 25.18 (30.38)* | 37.73 (30.38)* | 73.45 (29.58)* |
| O-Cell expansion under SLS load including pile self-weight | 5.4 (11.6)** | 13.6 (9.4)** | 8.2 (11.4)** | 3.1 (3.5)** |
| O-Cell expansion under ULS load including pile self-weight | 8.1 (14.9)** | 15.3 (13.1)** | 9.6 (16.1)** | 4.1 (5.1)** |
| Test pile | 1 | 2 | 2A | 3 |
|---|---|---|---|---|
| Maximum tested load (MN, upward/downward) | 51.65 (29.67) | 25.18 (30.38) | 37.73 (30.38) | 73.45 (29.58) |
| O-Cell expansion under | 5.4 (11.6) | 13.6 (9.4) | 8.2 (11.4) | 3.1 (3.5) |
| O-Cell expansion under | 8.1 (14.9) | 15.3 (13.1) | 9.6 (16.1) | 4.1 (5.1) |
*The value within () is the nominated test load as per PSTR (refer to Table 4); **The value within () is the predicted value prior to the testing
Sharing content requires targeting cookies to be enabled. Please update your cookie preferences to use this feature.