Micro-F1 score by model and outlier setting
| Model | Outliers | CNN2 | CNN3 | CNN4 | CNN5 |
|---|---|---|---|---|---|
| Raman | — | 0.982 | 0.986 | 0.989 | 0.989 |
| O | 0.980 | 0.983 | 0.983 | 0.986 | |
| LIBS | — | 0.997 | 0.998 | 0.999 | 0.998 |
| O | 0.996 | 0.994 | 0.997 | 0.998 | |
| UV–Vis | — | 0.989 | 0.990 | 0.988 | 0.984 |
| O | 0.975 | 0.983 | 0.976 | 0.982 | |
| NIR | — | 0.853 | 0.869 | 0.857 | 0.854 |
| O | 0.852 | 0.865 | 0.851 | 0.868 |
| Model | Outliers | CNN2 | CNN3 | CNN4 | CNN5 |
|---|---|---|---|---|---|
| Raman | — | 0.982 | 0.986 | ||
| O | 0.980 | 0.983 | 0.983 | 0.986 | |
| — | 0.997 | 0.998 | 0.998 | ||
| O | 0.996 | 0.994 | 0.997 | 0.998 | |
| UV–Vis | — | 0.989 | 0.988 | 0.984 | |
| O | 0.975 | 0.983 | 0.976 | 0.982 | |
| — | 0.853 | 0.857 | 0.854 | ||
| O | 0.852 | 0.865 | 0.851 | 0.868 |
micro-F1 score obtained for each model and spectroscopic technique without (—) or with (O) outlier detection; values in italics are the best metrics achieved for each technique; LIBS, laser-induced breakdown spectroscopy; UV–Vis, ultraviolet–visual; NIR, near infrared