Effect of choosing different start times for low minimum pressure
| Parameter | Case 4 | Case 5 | Case 6 | Units |
|---|---|---|---|---|
| Start line | 123 | 129 | 135 | |
| Maximum pressure | 670 | 660 | 651 | kPa |
| Minimum pressure | 75 | 75 | 75 | kPa |
| Uo (max − min) | 595 | 585 | 576 | kPa |
| Halfway pressure | 372·5 | 367·5 | 363 | kPa |
| Time to halfway (t50) | 76·4 | 79·0 | 82·0 | min |
| Uo/Cu | 2·98 | 2·93 | 2·89 | |
| ln(T50) | −0·130 | −0·175 | −0·216 | |
| T50 | 0·88 | 0·84 | 0·81 | |
| CH | 13·3 | 12·3 | 11·4 | m2/year |
| Parameter | Case 4 | Case 5 | Case 6 | Units |
|---|---|---|---|---|
| Start line | 123 | 129 | 135 | |
| Maximum pressure | 670 | 660 | 651 | kPa |
| Minimum pressure | 75 | 75 | 75 | kPa |
| 595 | 585 | 576 | kPa | |
| Halfway pressure | 372·5 | 367·5 | 363 | kPa |
| Time to halfway ( | 76·4 | 79·0 | 82·0 | min |
| 2·98 | 2·93 | 2·89 | ||
| ln( | −0·130 | −0·175 | −0·216 | |
| 0·88 | 0·84 | 0·81 | ||
| 13·3 | 12·3 | 11·4 | m2/year |