Table 3

Grid-refinement results. Raw values on every level and the Roache GCI for each consecutive triplet (refinement ratio 2, factor of safety 1.25)

Quantity/grid tripletΔx (m)ValueObserved order pGCI (fine)
Head-car suction peak (benchmark)1.02,288 Pa––
0.51,666 Pa––
0.251,263 Pa0.63 (pre-asymptotic)73.3%
0.1251,139 Pa1.706.0%
0.06251,105 Pa1.831.5%
Richardson value/3D CFD (Luo et al., 2017)–1,091/1,054 Pa–deviation +3.5%
Exterior peak-to-peak (baseline)4.04.426 kPa––
2.03.885 kPa––
1.03.639 kPa1.147.0%
Exterior peak-to-peak (A0 = 70 m2)4/2/16.064/5.571/5.298 kPa0.858.0%
Exterior peak-to-peak (L = 0.5 km)4/2/1/0.55.132/4.731/3.580/3.423 kPa−1.52 (4/2/1); 2.88 (2/1/0.5)not defined; 0.9%
Source(s): Author's own work