Displacements for a voltage of −400 V applied to MFC 1 and +1,200 V applied to MFC 4 (first test case)
| Point id | X [mm] | Y [mm] | Measured vertical displacement [mm] | |
|---|---|---|---|---|
| MFC 1 at −400 V, MFC 4 at +1,200 V | ||||
| Channels 1-2 | Channels 3-4 | |||
| 1 | 91 | −10 | 0.650 | 0.650 |
| 2 | 91 | 0 | 0.675 | |
| 3 | 91 | 10 | 0.675 | |
| 4 | 119 | −10 | 1.550 | 1.550 |
| 5 | 119 | 0 | 1.550 | |
| 6 | 119 | 10 | 1.575 | |
| 7 | 155 | −10 | 3.100 | 3.2 |
| 8 | 155 | 0 | 3.100 | |
| 9 | 155 | 10 | 3.125 | |
| 10 | 187.5 | −10 | 4.550 | 4.650 |
| 11 | 187.5 | 0 | 4.550 | |
| 12 | 187.5 | 10 | 4.600 | |
| 13 | 220 | −10 | 5.975 | |
| 14 | 220 | 0 | 5.975 | |
| 15 | 220 | 10 | 6.000 | |
| 16 | 256 | −10 | 7.175 | |
| 17 | 256 | 0 | 7.175 | |
| 18 | 256 | 10 | 7.250 | |
| 19 | 285 | −10 | – | |
| 20 | 285 | 0 | – | |
| 21 | 285 | 10 | – | |
| X [mm] | Y [mm] | Measured vertical displacement [mm] | ||
|---|---|---|---|---|
| MFC 1 at −400 V, MFC 4 at +1,200 V | ||||
| Channels 1-2 | Channels 3-4 | |||
| 91 | −10 | 0.650 | 0.650 | |
| 91 | 0 | 0.675 | ||
| 91 | 10 | 0.675 | ||
| 119 | −10 | 1.550 | 1.550 | |
| 119 | 0 | 1.550 | ||
| 119 | 10 | 1.575 | ||
| 155 | −10 | 3.100 | 3.2 | |
| 155 | 0 | 3.100 | ||
| 155 | 10 | 3.125 | ||
| 187.5 | −10 | 4.550 | 4.650 | |
| 187.5 | 0 | 4.550 | ||
| 187.5 | 10 | 4.600 | ||
| 220 | −10 | 5.975 | ||
| 220 | 0 | 5.975 | ||
| 220 | 10 | 6.000 | ||
| 256 | −10 | 7.175 | ||
| 256 | 0 | 7.175 | ||
| 256 | 10 | 7.250 | ||
| 285 | −10 | – | ||
| 285 | 0 | – | ||
| 285 | 10 | – | ||