Table 3.

Result variations between panels tested under different test procedures

 BS EN 594:2011BS EN 594:1996Variation: %
 Test 1Test 2 
Fmax: kN20·2220·13−0·4
R: N/mm1252·402281·1582·1
R1: N/mm1899·5151·7
R2: N/mm2662·78112·6
 Test 3Test 4 
Fmax: kN13·4113·601·5
R: N/mm597·15876·3631·9
R1: N/mm706·0218·2
R2: N/mm1046·7075·3
 Test 5Test 6 
Fmax: kN20·4021·896·8
R: N/mm1068·171828·1641·6
R1: N/mm1556·6845·7
R2: N/mm2002·0287·4
 Test 7Test 8 
Fmax: kN20·7820·76−0·1
R: N/mm1207·241975·9638·9
R1: N/mm1539·9627·6
R2: N/mm2411·9599·8
 Test 9Test 10 
Fmax: kN12·7610·52−21·4
R: N/mm650·601059·5038·6
R1: N/mm959·6847·5
R2: N/mm1159·3378·2