Simulation results of VISSIM under these two control strategies
| Control mode | Junction | Simulation flow (pcu) | Total simulated flow (pcu) | Simulated hourly flow (pcu) | Calculating hourly flow rates (pcu) | Delay for four intersection entrances (s) | Average delay (s) |
|---|---|---|---|---|---|---|---|
| General control | 1 | 90 | 350 | 1,350 | 1,525 | 31.42 | 30.38 |
| 2 | 84 | 1,260 | 1,323 | 29.18 | |||
| 3 | 94 | 1,410 | 1,536 | 31.43 | |||
| 4 | 82 | 1,230 | 1,223 | 28.86 | |||
| Front control | 1 | 94 | 361 | 1,410 | 1,525 | 30.46 | 29.13 |
| 2 | 86 | 1,290 | 1,323 | 27.39 | |||
| 3 | 99 | 1,485 | 1,536 | 30.69 | |||
| 4 | 82 | 1,230 | 1,223 | 27.56 |
| Control | Junction | Simulation | Total | Simulated | Calculating | Delay for | Average |
|---|---|---|---|---|---|---|---|
| General control | 1 | 90 | 350 | 1,350 | 1,525 | 31.42 | 30.38 |
| 2 | 84 | 1,260 | 1,323 | 29.18 | |||
| 3 | 94 | 1,410 | 1,536 | 31.43 | |||
| 4 | 82 | 1,230 | 1,223 | 28.86 | |||
| Front control | 1 | 94 | 361 | 1,410 | 1,525 | 30.46 | 29.13 |
| 2 | 86 | 1,290 | 1,323 | 27.39 | |||
| 3 | 99 | 1,485 | 1,536 | 30.69 | |||
| 4 | 82 | 1,230 | 1,223 | 27.56 |