Table 2.

Summary of test pit data and compliance with PAS128

Trial holeAssetTypeVerified materialDepth
(verified):
ABE
numbermmHVDepth: mmHVDepth: mmHVDepth: mm
1 and 17V1TelecomsPlastic – Conduit500B1TT500B1TF400B1TT550
V2TelecomsPlastic – Conduit500B1TT500B1TT500B1TT550
V3UnknownMetal – Pipe900N/AN/AN/AN/AB1TT900N/AN/AN/AN/A
V4WaterMetal – Pipe1050B2FT800B1TF800B2TT1120
V5ElectricMetal – Cable750B2TT600B1TF600B1TT810
2V1WaterCast iron – Pipe1050B2TT1100B1TF800B2TT930
V2ElectricCables550B1TT500B1TT500B1TF325
V3TelecomsPlastic – Conduit550B1TF350B1TT500B1TF430
V4ElectricCables550B1TT500B1TT500B1TT550
3V1WaterCast iron – Pipe940B2FF1100B1FF750B4N/AN/AN/A
4V1TelecomsPlastic – Conduit150B1FF190B1TF700B2TT150
V2TelecomsPlastic – Conduit150B1TF190B1TF700B1TT150
V3WaterPlastic – Pipe600N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
V4WaterCast iron – Pipe850N/AN/AN/AN/AB1TF600B2TT950
V5GasPlastic – Pipe500N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
V6ElectricMetal – Cable450B1TF230B1TT500N/AN/AN/AN/A
V7TelecomsPlastic – Conduit400B1TF200B1FF300B1TF250
5V1TelecomsPlastic – Conduit200B1FF380B1TF400B1TF500
V2TelecomsPlastic – Conduit200B1FF380B1TF380B1TF440
V3TelecomsPlastic – Conduit280B1TT220B1TF500B2TT250
V4TelecomsPlastic – Conduit280B1TF220B1TF500B2TT250
V5WaterPlastic – Pipe650N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
V6WaterPlastic – Pipe1150N/AN/AN/AN/AB1TF900B3TT1000
6V1ElectricCables500B1TT350B1TT500B2TT450
V2TelecomsPlastic – Conduit430B1TT350B1TT400B1TT380
V3ElectricCables500B1TT350B1TF300B2TT450
V4TelecomsPlastic – Conduit600B1TT500B1TF400B1TT535
V5TelecomsPlastic – Conduit600N/AN/AN/AN/AB1TF450B2FT480
7V1TelecomsPlastic – Conduit400B1TT450B1TT500B1TT500
V2TelecomsPlastic – Conduit400B1TT450B1TT400B2TF480
V3WaterCeramic – Pipe500N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
8 and 18V1WaterCast iron – Pipe780B2TT700B1TF600B2TT790
V2ElectricCable680B1TF500B1TF500B1TF490
V3WaterCeramic – Pipe500N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/A
V4ElectricCable450N/AN/AN/AN/AB1TT400B2TT490
V5TelecomsPlastic – Conduit400B1TT400B1TT400B1TT440
V6ElectricCable450B1TF150B1TF600N/AN/AN/AN/A
10V1TelecomsPlastic – Conduit240B1TF300B1TF200B2TF330
V2ElectricCables240B1?F300B1TF300B1TF360
V3ElectricCables240B1?F300B1TF300B1TF360
V4ElectricCables240B1?F300B1TF400B1TF360
V5WaterCeramic – Pipe330B1FF?B1FF?B1TF410
11V1ElectricCables440N/AN/AN/AN/AB1TF1000B1TF590
V2ElectricCables500B1FT500N/AN/AN/AN/AN/AN/AN/AN/A
V3TelecomsPlastic – Conduit390B1?T450B1FF300B1FT450
12V1ElectricCable – Beneath Ceramic Pipe650N/AN/AN/AN/AB1TF900N/AN/AN/AN/A
V2WaterCast iron – Pipe1000B2TF750B1TF700B2FT1120
V3ElectricCable – In Ceramic Pipe750B2TT550B1TF550B1TF885
16V1ElectricCable550B2TT550B1TF1100B1TT580
V2GasPlastic – Pipe350N/AN/AN/AN/AB1TT300N/AN/AN/AN/A

The table shows PAS128 assigned quality and accuracy levels for each test pit and its associated assets as detected by each company. Company C data are not included as it had the least representative