Experimental programme
| Test* | Height: mm | Diameter: mm | Confinement: MPa | Initial relative density: % | Initial porosity: % | Voxel size: μm | Number of scans |
|---|---|---|---|---|---|---|---|
| TCXL† | 24·2 | 10·7 | 0·1 | 46 | 35·2 | 15·57 | 18 |
| TCR | 22·3 | 10·1 | 7 | 47 | 35·0 | N/A | N/A |
| TCX1 | 23·5 | 9·4 | 7 | 58 | 38·8 | 15·57 | 7 |
| TCX2 | 23·3 | 9·9 | 7 | 54 | 38·4 | 15·50 | 6 |
| TCX3 | 23·4 | 9·3 | 7 | 57 | 38·4 | 8·82 | 2 |
| Test | Height: mm | Diameter: mm | Confinement: MPa | Initial relative density: % | Initial porosity: % | Voxel size: μm | Number of scans |
|---|---|---|---|---|---|---|---|
| TCXL | 24·2 | 10·7 | 0·1 | 46 | 35·2 | 15·57 | 18 |
| TCR | 22·3 | 10·1 | 7 | 47 | 35·0 | N/A | N/A |
| TCX1 | 23·5 | 9·4 | 7 | 58 | 38·8 | 15·57 | 7 |
| TCX2 | 23·3 | 9·9 | 7 | 54 | 38·4 | 15·50 | 6 |
| TCX3 | 23·4 | 9·3 | 7 | 57 | 38·4 | 8·82 | 2 |
TC, triaxial compression; X, with XCT; L, low confinement; R, reference test.
The results of test TCXL have already been presented in Andò et al. (2012), where the test was named COEA01.