Table 1.

Summary of data from laboratory experiments

CaseDistance from inlet: mDistance from wall: cmumax: cm/su*: cm/sH: mH/d50Froude numberReRemarks
Vegetated bank5·5015 (near vegetated bank)47·873·860·2003·810·246·81 × 104Q = 50 l/s
20 (centre)45·812·480·2003·810·298·24 × 104
6·0015 (near vegetated bank)50·594·030·1853·520·267·35 × 104S0 = −1·5%
20 (centre)48·587·580·1853·520·246·72 × 104
6·5015 (near vegetated bank)50·004·970·1823·460·267·16 × 104d50 = 0·0525 m
20 (centre)55·277·350·1823·460·287·90 × 104
6·7515 (near vegetated bank)50·085·580·1803·420·246·62 × 104 
20 (centre)54·634·300·1803·420·359·83 × 104
Bare bank5·5020 (centre)43·924·550·2003·810·215·96 × 104 
6·0020 (centre)54·602·240·1853·520·349·41 × 104 
6·5020 (centre)47·092·050·1823·460·318·60 × 104 
6·7620 (centre)55·546·240·1803·420·318·68 × 104 
Uniform flow5·5020 (centre)63·216·400·2003·810·267·41 × 104 
6·0020 (centre)63·006·860·2003·810·246·72 × 104 
6·5020 (centre)53·804·170·2003·810·277·52 × 104 
6·7620 (centre)53·722·930·2003·810·308·53 × 104 