Table 2.

Summary of CemSet parameters used to back-analyse pile test response (for all piles, shaft flexibility factor Ms = 0·0015 and friction centroid = 0·45)

Shaft diameter: mmBase diameter: mmShaft free length: mShaft friction length: mUltimate shaft friction: kNUltimate end-bearing: kNSoil modulus at pile base, Eb: kPa
Pile FO4805004·58·596014020 000
Pile FC4805004·58·596014020 000
Pile BO4805004·54·04001963150 000
Pile BC4805004·54·04301963120 000