List of ageing tests performed
| Test number | Mix water | Viscosity measurement procedurea | Duration: d | Objective |
|---|---|---|---|---|
| 1 | Deionised water | Brookfield viscometer, 3 r/min | 24 | To characterise the ageing behaviour of polymer fluids prepared using pure water |
| 2 | Brookfield viscometer, 20 r/min | 31 | ||
| 3 | Oxford tap water | Brookfield viscometer, 3 r/min | 23 | To characterise the ageing behaviour of polymer fluids prepared using hard water |
| 4 | Brookfield viscometer, 20 r/min | 33 | ||
| 5 | Deionised water | Marsh funnel | 80 | To assess the effect of viscosity measurement technique and long-term storage |
| Test number | Mix water | Viscosity measurement procedure | Duration: d | Objective |
|---|---|---|---|---|
| 1 | Deionised water | Brookfield viscometer, 3 r/min | 24 | To characterise the ageing behaviour of polymer fluids prepared using pure water |
| 2 | Brookfield viscometer, 20 r/min | 31 | ||
| 3 | Oxford tap water | Brookfield viscometer, 3 r/min | 23 | To characterise the ageing behaviour of polymer fluids prepared using hard water |
| 4 | Brookfield viscometer, 20 r/min | 33 | ||
| 5 | Deionised water | Marsh funnel | 80 | To assess the effect of viscosity measurement technique and long-term storage |
In the Brookfield viscometer tests, the shear rates experienced by the fluid are 0·66 and 4·4 s−1 for the rotational speeds 3 and 20 r/min, respectively (conversion factor equals 0·22 for spindle LV-1)