Table 2.

List of ageing tests performed

Test numberMix waterViscosity measurement procedureaDuration: dObjective
1Deionised waterBrookfield viscometer, 3 r/min24To characterise the ageing behaviour of polymer fluids prepared using pure water
2Brookfield viscometer, 20 r/min31
3Oxford tap waterBrookfield viscometer, 3 r/min23To characterise the ageing behaviour of polymer fluids prepared using hard water
4Brookfield viscometer, 20 r/min33
5Deionised waterMarsh funnel80To assess the effect of viscosity measurement technique and long-term storage
a

In the Brookfield viscometer tests, the shear rates experienced by the fluid are 0·66 and 4·4 s−1 for the rotational speeds 3 and 20 r/min, respectively (conversion factor equals 0·22 for spindle LV-1)