Parameters for determining the stability and the printability of a dispersion
| Parameter | Instrument | Principle | Target range |
|---|---|---|---|
| Stability behavior | |||
| Particle size distribution qr/particle size d | Laser diffractometer/syringe filter | Laser diffraction analysis/filtering method | dmax < (0.01−0.05 djet) (Derby and Reis, 2003) dmax < (0.02−0.05 djet) (Guo et al., 2017) |
| Zeta potential ζ | Zetasizer | Laser Doppler anemometry | ζ > +30 mV ∪ ζ < −30 mV (Greenwood, 2003; van Guyen et al., 2011), ζ > +15 mV ∪ ζ < −15 mV (White et al., 2007) |
| Zero shear viscosity η0 | Rotational rheometer | Rotation test | Standard value: 100–500 Pa⋅s (Wang et al., 1998) (predominantly depends on the particle volume fractions) |
| Storage modulus G’, loss modulus G”, loss factor δ | Rotational rheometer | Oscillation test | G” < G’ 0° < δ < 45° |
| Sedimentation behavior | Sedimentation test | Gray value analysis | Gray value change over time as small as possible |
| Printability | |||
| Viscosity in the flow area | Rotational rheometer | Rotation test | η0 at → at |
| Limiting high-shear viscosity | Capillary rheometer, rotational rheometer | Single-point measurement, extrapolation of the empirically obtained viscosity values in the flow area | at (specified by the printhead system) |
| Fluid dynamic numbers | – | – | Table 5 |
| Relaxation behavior | Rotational rheometer | Stress relaxation test | < 10–6 ms (Hoath, 2016) |
| Wetting behavior | Drop shape analyzer | Contact angle measurement | 0° < θ < 90° |
| Instrument | Principle | Target range | |
|---|---|---|---|
| Laser diffractometer/syringe filter | Laser diffraction analysis/filtering method | ||
| Zetasizer | Laser Doppler anemometry | ||
| Rotational rheometer | Rotation test | Standard value: 100–500 Pa⋅s ( | |
| Rotational rheometer | Oscillation test | G” < G’ | |
| Sedimentation test | Gray value analysis | Gray value change over time as small as possible | |
| Rotational rheometer | Rotation test | ||
| Capillary rheometer, rotational rheometer | Single-point measurement, extrapolation of the empirically obtained viscosity values in the flow area | ||
| – | – | ||
| Rotational rheometer | Stress relaxation test | < 10–6 ms ( | |
| Drop shape analyzer | Contact angle measurement | 0° < |