Summary of design information and driving criteria obtained from three tracks
| Track | Construction control method | Resistance factor for design, φ | Nominal resistance, Rn: kips (kN) | Contract pile length: feet (m) | Na | Resistance factors for construction control, φ | Rndr-EOD: kips (kN) |
|---|---|---|---|---|---|---|---|
| 1 | WEAP | 0·65 | 197 (877) | 75 (23) | 11 | φEOD = 0·65, φset-up = 0·20 | 166 (738) |
| 2 | Modified Iowa ENR formula | 0·60 | 213 (948) | 80 (24) | 11 | φ = 0·55 | 233 (1036) |
| 3 | WEAP and PDA-Capwap | 0·70 | 183 (814) | 70 (21) | 11 | φEOD = 0·75, φset-up = 0·40 | 141 (627) |
| Track | Construction control method | Resistance factor for design, | Nominal resistance, | Contract pile length: feet (m) | Resistance factors for construction control, | ||
|---|---|---|---|---|---|---|---|
| 1 | WEAP | 0·65 | 197 (877) | 75 (23) | 11 | 166 (738) | |
| 2 | Modified Iowa ENR formula | 0·60 | 213 (948) | 80 (24) | 11 | 233 (1036) | |
| 3 | WEAP and PDA-Capwap | 0·70 | 183 (814) | 70 (21) | 11 | 141 (627) |