Table 1

Values of TP,FN,TN,FP,TPR,FPR,FNR⁠, precision (PPV), and accuracy (Acc in %) of our ROC example when changes the threshold value.

ThresholdTPFNTNFPTPRFPRFNRPPVAcc
t1=∞010100001–50
t2=0.82191000.100.91.055
t3=0.80281000.200.81.060
t4=0.7528910.20.10.80.6755
t5=0.7037910.30.10.70.7560
t6=0.6246910.40.10.60.8065
t7=0.6055910.50.10.50.8370
t8=0.5455820.50.20.50.7165
t9=0.5055730.50.30.50.6360
t10=0.4964730.60.30.40.6765
t11=0.4564640.60.40.40.6060
t12=0.4073640.70.40.30.6465
t13=0.3973550.70.50.30.5860
t14=0.3782550.80.50.20.6265
t15=0.3282460.80.60.20.5760
t16=0.3082370.80.70.20.5355
t17=0.2682280.80.80.20.5050
t18=0.2391280.90.80.10.5355
t19=0.2191190.90.90.10.5050
t20=0.19100191.00.900.5355
t21=0.101000101.01.000.5050