Table 6

Double-line box arch tunnel lining crack pattern and quantity statistics

Tunnel segment numberCrack distribution characteristics
Longitudinal cracksTotal length of cracks/cm
QuantityPosition
7#3Left wall foot, right wall foot60
8#5Right arch foot, right wall foot, top of middle column, baseplate85
9#3Baseplate, left arch foot56
10#2Inside and outside of baseplate48
11#2Baseplate, bottom of middle column36
12#1Inside of baseplate26
Summary14Damage mainly concentrated in: inside and outside bottom plant, outside wall foot, outside arch foot311
Damage typeMainly large eccentricity damage
Cracking rangeThe hanging wall cracking range is 3.5 segments, 84 cm (1.75 D), and the footwall cracking range is 2.5 segments, 60 cm (1.25 D). The damage scope of the hanging wall is obviously larger than that of the footwall; the crack length of the hanging wall is 225 cm and that of the footwall is 86 cm. The damage degree of the hanging wall is greater than that of the footwall