Table 5
Data obtained during static analysis of the 3 studied holders
Original holder
New holder: Lattice 202
New holder: Lattice 28
Stress (MPa)
1.352
154.9
23.89
Safety stress factor
203.4
1.77
11.51
Displacement (mm)
0.000123
0.009717
0.002619
Strain (%)
0.00284
0.306
0.0572
Safety strain factor
352.11
3.27
17.48
Total CPU time (s)
1.3
429
27.6
Original holder
New holder: Lattice 202
New holder: Lattice 28
Stress (MPa)
1.352
154.9
23.89
Safety stress factor
203.4
1.77
11.51
Displacement (mm)
0.000123
0.009717
0.002619
Strain (%)
0.00284
0.306
0.0572
Safety strain factor
352.11
3.27
17.48
Total CPU time (s)
1.3
429
27.6