Table A1

Peak force and stiffness of the joints tested in the first experimental plan

Surface typePeak force (N)Stiffness (N/mm)
Symmetric single lap
Flat1747.531076.770833
Flat1675.351049.75
Flat1757.951026.604167
Flat1666.22991.9375
Flat1685.13957.8541667
Monolitic1524.95796.875
Monolitic1357.1863.9583333
Monolitic1390.13891.8333333
Interlocking916.65838.8541667
Interlocking1307.05943.3333333
Interlocking1284.9856.9791667
Interlocking1441.22901.2083333
Interlocking1400.28864.625
Asymmetric joggle lap
Flat670.4873.2291667
Flat880.23846.9166667
Flat722.53787.5
Flat799.6765.2083333
Monolitic1051.68788.2291667
Monolitic1040.2737.1875
Monolitic1407.65727.7083333
Interlocking1048.47764.0208333
Interlocking1131.43745.3541667
Interlocking1107.85685.0625
Interlocking1098.05699.125
Interlocking1180.63758.5416667
Double lap
Flat3357.651170.85
Flat3185.951174.78
Flat3243.381105.45
Flat3278.41020.75
Flat3222.31135.65
Monolitic2992.93973.58
Monolitic2950.031033.08
Monolitic3002.981099.306931
Interlocking1900.751140.564356
Interlocking2207.151133.08
Interlocking2600.531048.35
Interlocking2718.481108.1
Interlocking2391.431120.05