Table 3

Relevant values for scarf bonded joints

ValuesScarf joint 5°Scarf joint 10°Scarf joint 20°
Average peak force, applied in FE models (N)284925892315
Bonded area (mm2)933468238
Average stress (MPa)3.055.539.74
Structural peak peel stress on the midline (MPa)45.5844.0139.9
Structural peak shear stress on the midline (MPa)46.5844.4447.02
Critical structural stress obtained with equation (1) (MPa)∼ 58.5