Table VIII

Layer structure of the ground floor slab (from top to bottom, type C only)

Ground floor slab
MaterialThickness (mm)λ (W/mK)
Timber flooring100.140
Screed600.410
Sound insulation250.035
Reinforced concrete2502.300
Mineral fibre1250.035
U-value0.20 (W/m²K) 