Table 1

Example for non-metallized structure thermal resistance analysis – based on voltage, current source and receiver temperature measurements and power, temperature difference calculations

 VoltageCurrentPowerSource temperatureReceiver temperatureTemperature differenceThermal resistance
 UIPTSTRΔTRTH
Sample no[V][A][W][°C][°C][°C] or [K][K/W]
11.211.421.7299.798.90.80.46
21.261.642.0799.899.10.70.34
31.221.341.63100.299.30.90.55
41.520.640.9899.698.41.21.23
52.960.361.0810098.21.81.67
67.310.161.15100.199.40.70.61
74.410.180.7899.298.11.11.41
81.524.126.24100.399.11.20.19
91.482.283.37100.598.520.59
101.642.914.7610098.81.20.25
111.351.822.46100.198.71.40.57
      mean RTH0.72
      std. dev.0.47