Table 1

Literature review of studies on indoor assessment

City, countryStudyResultsReference
Dhaka (Bangladesh)Indicators of hospital IAQ and toxicity potentialsIAQ indicators had an overall average concentration of 104.1 ± 67.6 (PM1), 137.4 ± 89.2 (PM2.5), and 159.0 ± 103.3 (PM10µg/m3; 0.11 ± 0.02 (NO2), 1047.1 ± 234.2 (CO2), and 176.5 ± 117.7 (TVOC) ppmZaman et al. (2021) 
Sulaymaniyah (Iraq)Evaluation of CO2 levels, interior temperature, and relative humidityBuildings with non-centralized heating and unventilated systems have higher CO2 levels than those with centralized systems
Thermal comfort is influenced by weather and building placement
Alshrefy, Yousif, AL-Rifaee, and Mohammed (2020) 
Cairo (Egypt)IAP in houses varies seasonallyIn the summer, when ventilation rates are higher, IAP is heavily influenced by atmospheric levels, but interior concentrations are more influenced by indoor sources in the winter, when indoor activities are more prevalent and ventilation is lower
In both seasons, the volume of rooms and the number of occupants had an impact on indoor PM, CO, and CO2 levels
Abdel-Salam (2021) 
Akure (Nigeria)Evaluation of Akure, South West, Nigeria’s indoor air qualityIndoor PM1, PM2.5, and PM10 averages were 11.81, 10.03, and 7.242 µg/m3, respectivelyAbulude, Fagbayide, Akinnusotu, Makinde, and Elisha (2019) 
Addis Ababa (Ethiopia)Cook-stove indoor air pollution in EthiopiaClean, upgraded, and conventional stoves’ geometric means of PM varied from 10.8 to 235, 23.6–462, and 36.4–591 µg/m3, respectivelyEmbiale, Chandravanahi, Zewge, and Sahle-Demennie (2020) 
Desa, MalaysiaAn evaluation of air pollution at a construction site in MalaysiaThe outcome reveals that the mean PM10 levels were 62.71 µg/m3, the average PM2.5 levels was 18.32 µg/m3, and the average PM1 concentration is 14.04 µg/m3. When compared to PM2.5 and PM1, PM10 has the highest reading. The particulate matter content and climatic parameters do not significantly correlate. There is a strong correlation between some variables and the concentrations of CO, CO2, SO2, and NO2Saudi, Nurulshyha, Mahmud, and Rizman (2017) 
Nsukka, NigeriaNO2, SO2, and O3 indoor concentration levels in homes in Nsukka, NigeriaIn the kitchens, the indoor concentrations of NO2, SO2, and ozone range from 15 to 722 µg/m3 (median: 174, IQR: 74–336 µg/m3), 3–101 µg/m3 (median: 5, IQR: 4–9 µg/m3), and 2–46 µg/m3(median: 10, IQR: 5–15 µg/m3). Contrary to SO2 (3–4 µg/m3) and O3 (14–20 µg/m3) median levels, which were respectively similar in all rooms within the urban home, NO2 (94, IQR: 64–175 µg/m3) concentrations in kitchens were at least two times higher than in other roomsAgbo, Walgraeve, Eze, Ugwuoke, and Ukoha (2021) 
Taiyuan, ChinaAmong Students in Chinese Schools: A Longitudinal Investigation of Sick Building Syndrome (SBS) in Relation to SO2, NO2, O3, and PM10There were favorable correlations between the contaminants and the newly developing symptoms of the skin, mucosa, and overall healthZhang et al. (2014) 
Coimbra, PortugalPrimary schools air quality exploratory researchParticularly in the fall and winter, the highest concentration levels discovered inside the rooms were crucial (5,320 ppm). In a few schools, the highest concentrations of VOC and PM10 average concentrations surpassed the legal standard. CO, formaldehyde, NO2, SO2, and O3 levels (risk) were not significantFerreira and Cardoso (2013) 