Table 3

Results of testing the sealing performance of the low-phenyl silicone rubber sealing ring

No.Test itemTest resultsRequirements in Q/CR 706–2019
1Conventional leakage test at room temperature (kPa/min)0≤1
2Leakage test of the gap assembly at room temperature (kPa/min)0≤5
3Fracture testNo fractureNo fracture
4Conventional leakage test at low temperature (−50 °C for 24 h) (kPa/min)0≤2
5Leakage test of the gap assembly at low temperature (−50 °C for 24 h) (kPa/min)0≤12

Source(s): Authors’ own work