Table 3.

Parameters employed in each appraisal approach

Appraisal approachPermanent floor load: kN/m2Imposed floor load: kN/m2aPartial factor for permanent loadsPartial factor for imposed loadsPermanent load reduction factorImposed load combination factorTarget URMaterial strength: MPa
EC: Optimal compliance3.7–3.9b3.3d1.351.50e0.925e0.7e1.0355f
EC: Using experienced imposed loads3.7–3.9b0.63g1.35e1.50e0.925e0.7e1.0355f
EC: Using residential imposed loads3.7–3.9b2.0d1.35e1.50e0.925e0.7e1.0355f
EC: With average material strength3.7–3.9b3.3d1.35e1.50e0.925e0.7e1.0402i
EC: With reduced partial factor for permanent loads (γ)3.7–3.9b3.3d1.10h1.50ecc1.0355f
a

Additional imposed load of 0.6 kN/m2 (BSI, 2008) is assumed to act at roof level

b

Comprising: steel self-weight (0.5 kN/m2 per storey below seven storeys, 0.7 kN/m2 per storey seven storeys and above) (SCI, 2008)

c

No load reduction/combination factors applied due to their omission when deriving reduced partial factors (Kala, 2007)

d

Comprising 2.5 kN/m2 plus 0.8 kN/m2 for moveable partitions (BSI, 2002)

e

BSI (2011) 

f

BSI (2005) 

g

Orr and Drewniok (2018) 

h

Kala (2007) 

i

Melcher et al. (2004) 