Risk ownership matrix
| Structural performance | Fire performance | New service life (durability)c | Genuine/latent defects | |
|---|---|---|---|---|
| New structural elements | Structural engineer | Structural engineer | Structural engineer | Trade contractor |
| Existing (retained) structural elements where strengthened | Structural engineer | Fire engineer/structural engineer/architectb | Materials consultant/structural engineer | Trade contractor/insurance policy |
| Existing (retained) structural elements where subject to a change in design load or function | Structural engineer | Fire engineer/Structural engineer/architectb | Materials consultant | Insurance policy |
| Existing (retained) structural elements | Structural engineera | — | Materials consultant | Insurance policy |
| Structural performance | Fire performance | New service life (durability) | Genuine/latent defects | |
|---|---|---|---|---|
| New structural elements | Structural engineer | Structural engineer | Structural engineer | Trade contractor |
| Existing (retained) structural elements where strengthened | Structural engineer | Fire engineer/structural engineer/architect | Materials consultant/structural engineer | Trade contractor/insurance policy |
| Existing (retained) structural elements where subject to a change in design load or function | Structural engineer | Fire engineer/Structural engineer/architect | Materials consultant | Insurance policy |
| Existing (retained) structural elements | Structural engineer | — | Materials consultant | Insurance policy |
Highlighted items may require changes and variation dependent on scope preferences, notation and so on
Depending on the element, protection will be specified by the structural engineer (i.e. cover requirements to concrete elements)
Generally assumed that the building's new service life matches Eurocode requirements