Table 3.

Key details recorded in reuse passporting

CategoryDetails recorded
Original applicationSource structure, historical use and prior loading conditions
Dimensional verificationWeb and flange thickness and section depths. Level of conformity with tolerances
Certified mechanical propertiesYield strength, tensile strength, elongation and compliance with Eurocodes
Inspection and testing reportsVisual inspections, non-destructive testing and hardness testing
Surface conditionCorrosion levels, coatings and any required surface treatment
Fabrication featuresExisting bolt holes, stiffeners and prior modifications
Structural classificationFully compliant sections and those needing minor adaptation
Project certificationStructural engineer approval (HTS) confirming fitness for reuse