Table 3.

Exploration of thermal removal efficiency under different boundary conditions with semi-transverse and full-transverse ventilation systems

No.Tunnelheight: mHRR:MWExhaustrate Qexhaust:m3/sNatural supplyrate: m3/sCyclicspace: mSFTL: mForced supply rate equal to minimum semi-transverse natural:air-makeup rate:m3/sηξ
15.233.618–24-240to24035900.8250.175
25.211.56.831.5-240to24046400.9550.045
35.2201044.4-240to24044500.9440.056
45.611.53.622.3-320to32062801.006−0.006
55.6206.834.5-300to30057500.9740.026
65.631032.383-140to14025500.6560.344
76203.626.43NULL78701.012−0.012
8636.825–35-240to24029400.7730.227
9611.51044–51-260to26043200.8800.12
S15.233.636020.660.82740.1726
S25.211.56.845631.50.96220.0378
S35.2201044044.40.94370.0563
S45.611.53.661422.30.99790.0021
S55.6206.857834.50.9510.049
S65.631025032.3830.6630.337
S76203.676126.431.014−0.014
S8636.829128.6140.7690.231
S9611.51043444.70510.8670.133