Table 5.

Numerical application of parameters, boundary and initial conditions, along with parameters used for heat generation rate

Parameters used as initial and boundary conditionParameters used to calculate the generated heat
T0 = 21.7 °C initial temperatureλ = 808 nm laser wavelength
Tw = 21.7 °C free stream temperatureεc + j·εcj = –24.8731 + j·1.4178 complex permittivity of the gold
T = 22.5 °C external radiation temperatureεh = 1.7455 complex permittivity of the hosting medium
hext = 14 W/(m2 · K) convective heat transfer coefficientI0 = 32000 W/m2 incident light intensity
ε = 0.94 relative emissivityθ = 0 °C incident angle
Source: Table created by authors