The line chart plots tolerance field in millimetres across the life cycle of component. The vertical axis ranges from minus 0.500 to 0.500 millimetres. The horizontal axis lists additive printing, heat treatment, machining, coating, 15 840, 28 600, 36 300, 42 400, 48 825, and 66 400. The legend lists 1 u, 1 d, 2 u, 2 d, 3 u, 3 d, 4 u, 4 d, 5 u, 5 d, 6 u, and 6 d. A shaded tolerance band is labelled tolerance plus or minus 0,200. Most plotted series remain within the tolerance band across the life cycle. The 1 u and 1 d series fall below the band at 42 400 and stay below it at 48 825. The 6 u and 6 d series rise above the band after heat treatment, then return within the band. Insets identify measurement positions around the component.Development of 3D CNC CMM dimensional deviations of measured points in the crown area of the component
Source(s): Authors’ own work
Sharing content requires targeting cookies to be enabled. Please update your cookie preferences to use this feature.