The horizontal axis shows Q over Q 0 from 10 power 0 to 10 power 2. The vertical axis shows d over d 0 from 10 power 0 to 10 power 1. Square markers cluster between about 2 and 10 on Q over Q 0 and about 1 and 3 on d over d 0. The fitted line increases from about 1 to above 5 as Q over Q 0 increases.
Non-dimensional jet diameter vs non-dimensional flow rate
Note(s): All simulations except the pure electrospray cases are plotted. The solid line represents the theoretical prediction [equation (13)], and simulated data points are represented with empty squares