Figure 3.
A three-dimensional safety factor model of the chamber assembly ranges from 0.26 minimum to 15 maximum, with a marked value of 1.8.The three-dimensional model presents the chamber assembly with its upper structure, central components, surrounding housing, actuators and external equipment. The safety factor scale ranges from 0.26 minimum through 3, 6, 9 and 12 to 15 maximum. The upper plate, internal plate, vertical supports and chamber housing carry varying safety factor values across their surfaces. A callout on the chamber identifies a safety factor of 1.8. The coordinate indicator identifies X, Y and Z directions.

Finite-element analysis of the GeoTriax cell. The minimum safety factor of approximately 1.8 occurs in localised regions near welds and structural junctions, while most of the assembly exhibits safety factors between 6 and 12, indicating adequate structural performance