Skip to Main Content
Article navigation
Purpose

The present work primarily aims to study the corrosion characterization of tubular steel API‐P110 in high H2S containing solution with or without CO2.

Design/methodology/approach

Corrosion behaviors of steel in buffered solutions containing 50 percent H2S and various levels of CO2 concentration were investigated via weight‐loss method, SEM and EDS. The effects of CO2 on corrosion occurred on the metal were analyzed by electrochemical techniques.

Findings

Corrosion rates of steel decreased as the CO2 content in H2S/CO2 solution increased. It was observed for the tubular steel to experience an increase in corrosion rate at concentrations 17 percent CO2 or 34 percent CO2 in 50 percent H2S while when further increasing concentration of CO2 to 50 percent the corrosion rate decreases. Increased CO2 content in H2S/CO2 led to fewer anions desorbing and fewer reactants adsorbing, e.g. H+, H2CO3. As a result, cathodic reaction rate decreased and the amount of hydrogen absorbed decreased.

Originality/value

The experimental results showed that corrosion alleviated when increasing CO2 content in high H2S and CO2 containing environment.