Skip to Main Content
Article navigation
Purpose

The purpose of this paper is to research the morphologies of the oxide films formed on the internal surfaces of water wall tubes in a 600 MW furnace at 300° while using CPT, CT, AVT(R) and AVT(O) water chemistry. In these water chemistry conditions, a layer of oxide film spontaneously forms in the furnace wall which could prevent corrosions in boiler water directly contact with the inner tube and reduce the probability of tube perforation.

Design/methodology/approach

The different morphologies, specific functions and distribution in the oxide film were identified by electrochemical workstation, XRD, SEM and EDAX.

Findings

It is concluded that metal surface was rugged and had deep corrosion in CPT. Ions penetrated into the oxides of large particles with gaps and intergranular corrosion occurred in CT conditions. In AVT(R), the oxide film uniformly covered on the metal surface played a protective role, but could be easily washed away by solution. The oxide film formed in AVT(O) was similar to AVT(R), but the difference is that large solid particles of Fe2O3 cover the outermost oxide film, which prevents the oxide film from being taken away by the flowing solution. In consequence, the degree of corrosion sustained by the tube walls is lowest in the case of AVT(O).

Originality/value

The results can provide reference for reducing the high temperature corrosion of metal in the actual operation.

You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal