Purpose

The purpose of this paper is to focus on life cycle cost analysis (LCCA) of 1 MW roof-top Solar Photovoltaic (PV) panels installed in warm and humid climatic region in Southern India. The effect of actual power generated from solar PV panels on financial indicators is evaluated.

Design/methodology/approach

LCCA is done using the actual power generated from solar PV panels for one year. The net present value (NPV), internal rate of return (IRR), simple payback period (SPP) and discounted payback period (DPP) are determined for a base case scenario. The effect of service life and the differences between the ideal power expected and the actual power generated is evaluated.

Findings

A base case scenario is evaluated using the actual power generation data, 25-year service life and 6 percent discount rate. The NPV, IRR, SPP and DPP are found to be INR 13m, 8 percent, 10.9 years and 18.8 years respectively. It is found that the actual power generated is about one-third less than the ideal power estimated by consultants prior to project bidding. The payback period increases by 70–120 percent when the actual power generated from solar PV panels is considered.

Originality/value

The return on investment calculated based on ideal power generation data without considering the operation and maintenance related aspects may lead to incorrect financial assessment. Hence, strategies toward solar power generation should also focus on the actual system performance during operation.

Licensed re-use rights only
You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$39.00
Rental

or Create an Account

Close Modal
Close Modal

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Please sign in to your personal account to gift article access.

Register

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

Each link will stop working after 30 days or 10 uses. You may create up to 10 links in a 30 day period.

Gift articles remaining: --

Gift article access

As a benefit of your subscription, you can share temporary access to restricted articles.

Each link will stop working after 30 days or 10 uses.

You have reached the limit of 10 links within a 30 day period.