The purpose of this paper is to present the methodology of designing an exciter for Magnetic Induction Tomography (MIT). The design of the exciter must satisfy the following requirements: maximize MIT system sensitivity and minimize harmful influence on electronic MIT equipment.
Two objective functions are considered, namely: a magnetic flux density in the protected regions and a module of the eddy‐current density vector in the object under test in the vicinity of a sensor. The paper shows a multi‐objective optimization technique (based on the weighted sum method) which, by coupling the finite‐element method with a genetic algorithm, supports the design of the exciter.
It is possible to design in a relatively simple way an exciter for MIT under the given assumptions.
Detailed description of the multi‐objective optimization procedure has been presented.