Skip to Main Content
Keywords: Magnetic steel slabs
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
COMPEL (2017) 36 (2): 436–444.
Published: 06 March 2017
...) coils. Findings The feasibility of in-depth induction heating of a 200 × 1,000 × 5,000 mm magnetic steel slab with an applied 2 T DC saturating field is numerically investigated. The results show that the use of a DC saturating field leads to shorter processes which fulfil the heating objectives...