Great savings can be achieved by detecting and isolating design problems early in an electronic programme. Many design problems, including electrical overstress, poor thermal design and circuit layout problems, are detectable by their infrared (I‐R) signature. A reliability and design improvement tool utilising current I‐R scanning technology has been developed. Specifically, an I‐R scanning method for making accurate temperature measurements for the purpose of electronic design reliability improvement and qualification has been developed and verified experimentally. Field‐actual conditions, in which radiative and convective heat losses from the components are negligible, are simulated with a thermally insulating enclosure. The enclosure is designed for rapid removal just before the scan, obviating the need for exotic materials that are transparent to I‐R in the scanner's passband. With typical hardware thermal lags, the method allows determination of true temperatures simulating field conditions. Corrections for unwanted scanner‐produced radiation and for the target emissivity are made with a three‐scan method and specially designed apparatus. An integral part of this apparatus is the aforementioned quickly removable thermal enclosure. The three scans take approximately an hour for a typical circuit board after initial set‐up time. True‐temperature measurements of circuit boards can be made with the I‐R design improvement tool now.
Article navigation
1 January 1986
Review Article|
January 01 1986
True Temperature Measurement of Electronic Components Using Infra‐red Thermography Available to Purchase
J.M. Kallis;
J.M. Kallis
Hughes Aircraft Company, El Segundo, California, USA Now at Motorola Inc., Phoenix. Arizona.
Search for other works by this author on:
A.H. Samuels;
A.H. Samuels
Hughes Aircraft Company, El Segundo, California, USA Now at Motorola Inc., Phoenix. Arizona.
Search for other works by this author on:
R.P. Stout
R.P. Stout
Hughes Aircraft Company, El Segundo, California, USA Now at Motorola Inc., Phoenix. Arizona.
Search for other works by this author on:
Publisher: Emerald Publishing
Online ISSN: 1758-602X
Print ISSN: 0305-6120
© MCB UP Limited
1986
Circuit World (1986) 12 (2): 25–30.
Citation
Kallis J, Samuels A, Stout R (1986), "True Temperature Measurement of Electronic Components Using Infra‐red Thermography". Circuit World, Vol. 12 No. 2 pp. 25–30, doi: https://doi.org/10.1108/eb043795
Download citation file:
Suggested Reading
Assessing building façades using infra‐red thermography
Structural Survey (June,1998)
Application of infrared thermography in the characterization of voids and honeycomb in concrete structure: Experimental results and numerical simulations
International Journal of Structural Integrity (May,2014)
Building defects diagnosis by infrared thermography
Structural Survey (December,2004)
Developments in Assessing the Structural Integrity of Applied Surfaces to Concrete Buildings
Structural Survey (August,1994)
Thermography techniques for integrated circuits and semiconductor devices
Sensor Review (September,2007)
Related Chapters
Pulsed thermography using infra-red TV for in-reactor structural inspection
Remote techniques for hazardous environments
NEW SUGGESTIONS TO MEASURE THE CORROSION LEVEL OF REINFORCEMENT USING INFRARED THERMOGRAPHIC TECHNOLOGY
Repair and Renovation of Concrete Structures: Proceedings of the International Conference held at the University of Dundee, Scotland, UK on 5–6 My 2005
Remote sensing techniques for bridge deck evaluation
Bridge Management 5: Inspection, maintenance, assessment and repair: Proceedings of the 5th International Conference on Bridge Management, organized by the University of Surrey, 11–13 April 2005
Recommended for you
These recommendations are informed by your reading behaviors and indicated interests.