Skip to Main Content
Article navigation
Purpose

This paper aims to present a methodology for estimating the risk of component level electrical bridging failures from unattached conductive (tin) whiskers.

Design/methodology/approach

Based on experimental data an algorithm was developed and assessed by further experiments. The risk estimate is based on whisker parameters, generated from experiments over a period of time. A bridging failure risk is defined as the probability of a conductive whisker landing between two isolated electrical conductors. A probabilistic estimate for electrical bridging failure risk is achieved by randomly sampling distributions of conductive whisker length, deposition angle, and density for a defined electrical structure. A fine pitch quad flat package attached to a printed wiring board is used as test vehicle to verify the risk estimate.

Findings

The estimated risk is found to be higher than planned in the experimental test. The lower experimentally determined risk was found to be the result of high contact resistance between the conductive whisker and the electrical conductors that form the unintended circuit. Contact resistance between the whisker and electrical conductors was found to mitigate the whisker shorting risk.

Originality/value

This is the first attempt to quantify the risk failure due to unattached conductive whiskers in electronic products. A methodology for estimating electrical bridging risk due to unattached conductive whiskers is provided. Contact resistance of conductive whiskers is found to be a critical issue that may be mitigate failure risks.

You do not currently have access to this content.
Don't already have an account? Register

Purchased this content as a guest? Enter your email address to restore access.

Please enter valid email address.
Email address must be 94 characters or fewer.
Pay-Per-View Access
$41.00
Rental

or Create an Account

Close Modal
Close Modal